Archived page - correct page is here |
Photoluminescent vinyl PVC-sheets - Test results
Archived page - no
longer updated Measurement A Illuminance sample: E=251.3 lux for 20 min Type of lighting source: Warm/white light tubes. Sample stored in total darkness for 24 hours before test was carried out. Luminance after 10 minutes: 275.9 mcd/m2 Luminance after 30 minutes: 110.7 mcd/m2 Luminance after 60 minutes: 56.3 mcd/m2 Luminance after 120 minutes: 27.4 mcd/m2 Lowest visible threshold of 0.3 mcd/m2 reached after: 8467 minutes Measurement B* Illuminance sample: E=1000 lux. Type of lighting source: Xenon-lamp Sample stored in total darkness for 6 hours before test was carried out. Luminance after 10 minutes: 743.0 mcd/m2 Luminance after 30 minutes: 255.6 mcd/m2 Luminance after 60 minutes: 120.4 mcd/m2 Luminance after 120 minutes: 58.8 mcd/m2 Lowest visible threshold of 0.3 mcd/m2 reached after : 18030 minutes Measurement C** Illuminance sample: E=998.1 lux for 5 min. Type of lighting source: Xenon-lamp Sample stored in total darkness for 12 hours before test was carried out. Luminance after 10 minutes: 609.2 mcd/m2 Luminance after 30 minutes: 201.5 mcd/m2 Luminance after 60 minutes: 94.7 mcd/m2 Luminance after 120 minutes: 45.5 mcd/m2 Lowest visible threshold of 0.3 mcd/m2 reached after: 13158 minutes * Measurement according to DIN 67510 Part 2. Measurements carried
out 6th-8th September 2000.
* Value evaluated from readings >= 15 minutes.
|
Photos of directional signs before mounting Brannfarlig isolasjon i bytunnel (Norwegian only).
|
Contact information: |
||
Metal Safe Sign International |
||